Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nucl Med Commun ; 38(9): 729-736, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28704342

RESUMO

INTRODUCTION: Hybrid imaging has proven to be a major innovation in nuclear medicine, allowing the fusion of functional information with anatomical detail. In the past, the use of hybrid imaging such as PET-CT, PET-MRI and SPECT-CT has been of great clinical benefit; however, these scanners are relatively large and bulky. We have developed and investigated the clinical application of a compact small field of view hybrid gamma camera (HGC) that is suitable for small-organ imaging at the patient bedside. PATIENTS AND METHODS: The HGC - consisting of a CsI(Tl) scintillation crystal coupled to an electron-multiplying charge-coupled device and an optical camera - was used in this study. Eligible patients attending the nuclear medicine clinic at Queen's Medical Centre, Nottingham University Hospitals NHS Trust, Nottingham, UK, were invited to take part in this study. Following the standard injection of either a Tc-labelled or I-labelled radiopharmaceutical, images of the patient were acquired using the HGC and presented in a fused optical-gamma display. RESULTS: There were 24 patients enrolled in the study (age range between 30 and 83 years, mean: 58.6 years), images of 18 of whom were successfully acquired. These included patients who were undergoing bone, thyroid, lacrimal drainage, DaTscan and lymphatic imaging. In general, the small field of view system was well suited to small-organ imaging. The uptake could be clearly seen in relation to the patient surface anatomy and showed particular promise for lymphatic, thyroid and lacrimal drainage studies. CONCLUSION: This pilot study has demonstrated the first clinical results of hybrid optical-gamma imaging in patients. The use of this system has raised new possibilities for small-organ imaging, in which the localization of radiopharmaceutical uptake can be presented in an anatomical context using optical imaging. The compact nature of the hybrid system offers the potential for bedside investigations and intraoperative use.


Assuntos
Câmaras gama , Aumento da Imagem/instrumentação , Cintilografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Miniaturização , Imagens de Fantasmas , Projetos Piloto , Cintilografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Nucl Med Commun ; 36(11): 1134-42, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26352214

RESUMO

OBJECTIVE: To develop a method for the assessment of small field of view (SFOV) gamma cameras using a novel phantom designed to simulate the localization of sentinel nodes in the presence of a high-activity injection site. MATERIALS AND METHODS: The phantom consisted of a cube-shaped acrylic glass support frame. Sixteen acrylic glass plates and nine bars were stacked within the frame to allow a variable configuration of the simulated node depth and node-to-injection site separation. Syringes filled with Tc were used to simulate activity at the injection site and node. Scintigraphic imaging was carried out and the images were assessed subjectively and quantitatively through calculation of the contrast-to-noise ratio. The detection performance of an SFOV gamma camera was then compared with that of a large field of view gamma camera. RESULTS: The detectability studies showed that the SFOV gamma camera could detect low activity in nodes by visual examination of images and with contrast-to-noise ratios ranging from 3 to 62. In particular, the phantom showed the limits of node detection using an SFOV gamma camera over activity ratios less than 1 : 100 and at depths below 45 mm with 25 mm of node-to-injection site separation. Visual subjective assessment of images acquired under the same conditions showed that the SFOV gamma camera was superior to a large field of view camera for the detection of nodes at a node-to-injection site separation of 25 mm. CONCLUSION: A low-cost phantom has been designed and fabricated that provides a versatile method for the assessment of SFOV gamma cameras intended for sentinel node imaging.


Assuntos
Câmaras gama , Biópsia de Linfonodo Sentinela/instrumentação , Desenho de Equipamento , Imagens de Fantasmas , Razão Sinal-Ruído
3.
Clin Nutr ; 30(2): 165-71, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20971535

RESUMO

BACKGROUND & AIMS: Supplementing preoperative carbohydrate drinks with glutamine may lead to benefits in addition to reducing insulin resistance, but amino acids may delay gastric emptying (GE). The effects of supplementing a preoperative carbohydrate drink (CCD) with glutamine or lipid on GE were studied. METHODS: Ten healthy male volunteers ingested 410 ml of one of three isocaloric-isovolumetric carbohydrate-based drinks labelled with (99m)Tc-DTPA: CCD (preOp(®), Nutricia, UK, 50 g carbohydrate), CCD/G (preOp(®), 36 g carbohydrate + 15 g glutamine) or CCD/L (preOp(®), 36 g carbohydrate + 7 g lipid) in this randomized, blinded, three-way crossover study. After baseline measurements, GE was measured scintigraphically and blood sampled for insulin, glucose and glucagon-like peptide 1 (GLP-1) at 20 min intervals for 240 min. RESULTS: Mean (95% CI) T(90) GE times for CCD, CCD/G and CCD/L were 101 (87-115), 95 (84-107) and 87 (72-102) min, respectively. At 40 min postprandially, mean (SEM) concentrations of glucose (mmol/l) and insulin (mIU/l) were 7.5 (0.5) and 35 (5) for CCD; 6.2 (0.2) and 28 (4) for CCD/G; and 7 (0.3) and 31 (5) for CCD/L, respectively. There were no differences in postprandial GLP-1 concentrations. CONCLUSIONS: Glutamine and lipid supplementation did not prolong the GE of CCD but did 'blunt' postprandial glucose and insulin responses, independent of GLP-1 concentrations. Registered under ClinicalTrials.gov Identifier no. NCT00943020.


Assuntos
Bebidas , Carboidratos/administração & dosagem , Esvaziamento Gástrico/efeitos dos fármacos , Glutamina/administração & dosagem , Lipídeos/administração & dosagem , Cuidados Pré-Operatórios , Adolescente , Adulto , Glicemia/análise , Metabolismo dos Carboidratos , Carboidratos/farmacologia , Estudos Cross-Over , Suplementos Nutricionais , Ingestão de Alimentos , Etnicidade , Peptídeo 1 Semelhante ao Glucagon/sangue , Glutamina/farmacologia , Humanos , Insulina/sangue , Resistência à Insulina , Lipídeos/farmacologia , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Pentetato de Tecnécio Tc 99m , População Branca , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...